EN-Synergis Controllers

Mercury EP1501 intelligent controller

Issue link: https://resources.genetec.com/i/1343470

Contents of this Issue

Navigation

Page 1 of 1

part of HID Global The Authentic Mercury open platform delivers quality assurance derived from the most proven and reliable hardware in the industry. Driven by our engineering excellence and technology leadership, Authentic Mercury hardware is designed as an access control platform that easily encompasses emerging technologies, changing industry standards and evolving system environments. Make yours Authentic, Make sure its Merc. PoE+ Edge-capable Intelligent Controller LP1501 Network Switch Door 1 CAT5/CAT 6 To Mercury OEM Host Door 1 MR62e Door 1 MR52 MR16OUT TB5 MR16IN MR50 Door 2 TB1 1 TB2 1 TB3 1 TB4 1 TB7 1 TB5 1 TB6 1 VO GND VIN GND VIN POE J5 K1 K2 K3 K4 K4 K3 K2 K1 J3 J4 J1 10519-0000-F, REV-A 7 6 5 4 3 2 1 2 3 4 1 S1 ON | | V TB1 TB2 TB3 TB4 TB9 I1 I1 I2 I2 I3 I3 I4 I4 I5 I5 I6 I6 I7 I7 I8 I8 CT GND BA GND TB11 VIN GND TR- GND TR+ TB10 VOUT 1 2 3 4 5 6 7 8 S1 A B K1 K2 TB5 I9 I9 I10 I10 TB6 I11 I11 I12 I12 TB7 I13 I13 I14 I14 TB8 I15 I15 I16 I16 1 2 3 4 S2 ON--> RS-485 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 CT BA NC C NO NC C NO OUT 1 OUT 2 TB12 K1 K2 J3 NC C NO NC C NO OUT 8 OUT 7 NO C NC NO C NC OUT 6 OUT 5 NO C NC NO C NC OUT 4 OUT 3 NO C NC NO C NC OUT 2 OUT 1 NO C NC NO C NC OUT 9 OUT 10 C NO NC C NO NC OUT 11 OUT 12 NC C OUT 13 NO NC OUT 14 NO C OUT 16 NO C OUT 115 NC C NO NC TR+ GND TR- RS-485 GND VIN GND BA CT GND VOUT TB10 TB9 TB11 J1 S1 1 2 3 4 5 6 7 8 A B CT BA TB4 TB3 TB2 TB1 TB5 TB6 TB7 TB8 1 2 3 4 S2 K1 K2 K3 K4 K5 K6 K7 K8 K9 K10 K11 K12 K13 K14 K15 K16 1 2 4 3 5 12 9 7 6 8 13 14 10 11 15 16 TB1 GND TR- TR+ VO D0 DAT GND D1 LED CLK BZR TB4 J1 J2 D1 D2 D4 D3 TB3 TB2 I1 I1 I2 I2 GND VIN C NC NO C NO NC K2 K1 K2 K1 S1 8 5 6 7 4 1 2 3 ^ | ON INPUTS IN1 IN2 IN3 IN4 TB1 TB2 TB3 IN5 IN6 TB4 IN7 IN8 TB5 TMP GND PFL GND TR- NC NC GND TR+ TB6 RS-485 TB7 VIN GND VOUT A NC NO C NC RLY 1 C NO RLY 2 RLY 4 RLY 3 NO C NO NC C NC RLY 6 RLY 5 NO C NO NC C NC TB10 TB11 TB12 READER 2 VO LED BZR CLK DAT GND D1 D0 VO LED BZR CLK GND D1 D0 DAT READER 1 TB8 TB9 12V PT J1 K1 K2 K3 K4 K5 K6 J4 1 4 3 2 ^ | ON 1 4 3 2 5 8 7 6 S1 S2 MR52+ VO V LED BZR CLK AT D1 0 READER 1 TB1 TB2 TB3 1 1 1 TB1 TB5 1 TB4 1 TB5 7 6 5 4 3 2 1 J7 3 4 S1 2 1 J5 J6 K2 K1 12V PoE J3 ON V | | | | | | RS-485 LP1501 LP1501_July_2019 Specifications Access Control 240,000 cardholder capacity 50,000 transac on buffer Supports total of 1 RS-485 IO protocol 255 access levels per cardholder Cardholder - 19 Digit (64 Bit) User ID with 15 digit PIN MAX Ac va on/Deac va on If/Then macro capabili es An -passback support Nested, area, hard, so and med forgiveness Adjustable cardholder capacity Supports up to 130 inputs and 130 outputs Door Control Na vely supports for up to 2 readers and 1 opening. Using on-board OSDP, device controls 1 door and up to 2 OSDP mul -dropped readers. When not using on-board OSDP reader, device can expand to support up to 17 readers and openings in total Power Input PoE (12.95 W), compliant to IEEE 802.3af or PoE+ (25 W), compliant to IEEE 802.3at or 12 Vdc +/- 10 %, 1.8 A maximum Power Output PoE: 12 Vdc @ 625 mA including reader and AUX output * PoE+ or external 12 Vdc: 12 Vdc @ 1.25 A including reader and AUX output * * Excluding micro USB port Micro USB Port 5 Vdc maximum (deduct 270 mA from reader and Auxiliary Power output) Ba ery SRAM Backup Ba ery, rechargeable Host Comm. Ethernet: 10-BaseT/100Base-TX Inputs Two unsupervised/supervised, Programmable End-of-Line resistors, 1k/1k ohm, 1 %, ¼ wa standard One unsupervised input dedicated for cabinet tamper Output Relays Two relays: Form-C contacts: 2 A @ 30 Vdc, resis ve Reader Interface Reader Power 12 Vdc ± 10 %: PoE, PoE+ or local power supply, 300 mA maximum Data Inputs Reader port 1: TTL compa ble, F/2F or 2-wire RS-485 Reader port 2: TTL compa ble or F/2F LED Output TTL compa ble, high > 3 V, low < 0.5 V, 5 mA source/sink maximum Buzzer Output Open collector, 12 Vdc open circuit maximum, 40 mA sink maximum Specifications Cable Requirements Power and Relays 1 twisted pair, 18 AWG (when using local 12 Vdc power supply) Ethernet CAT-5, minimum Reader TTL 6-conductor, 18 AWG, 500 . (152 m) maximum Reader F/2F 4-conductor, 18 AWG, 500 . (152 m) maximum Reader RS-485 1 twisted pair, shielded. 24 AWG, 120 ohm impedance, 2000 . (610 m) maximum Alarm Input 1 twisted pair per input, 30 ohms maximum Alarm Output As required for the load Environmental Temperature -55 to 85 °C storage, 0 to 70 °C opera ng Humidity 5 to 95% RHNC Mechanical Dimensions 5.5 in. (140 mm) W x 2.75 in. (70 mm) L x 0.96 in. (24 mm) H without bracket 5.5 in. (140 mm) W x 3.63 in. (92 mm) L x 1.33 in. (34 mm) H with bracket Weight 3.6 oz. (103 g) without bracket 4.43 oz. (125.5 g) with bracket Product Compliance UL294 Recognized 1 , FCC Part 15 Class A, CE Compliant, RoHS (2011/65/EU & 2015/863), EU REACH (1907/2006), California Proposi on 65, NIST Cer fied Encryp on Warranty Mercury Security warrants the product is free from defects in material and workmanship under normal use and service with proper maintenance for one year from the date of factory shipment. 1 For UL, the Power Sourcing Equipment (PSE) such as a PoE or PoE+ enabled network switch and/or PoE or PoE+ power injectors must be UL Listed under UL294B.

Articles in this issue

view archives of EN-Synergis Controllers - Mercury EP1501 intelligent controller