EN-Synergis Locks

Allegion Schlage AD-300 Networked hardwired electronic lock

Issue link: https://resources.genetec.com/i/1343938

Contents of this Issue

Navigation

Page 1 of 3

Schlage • AD-300 AD-300 electronic lock specifications Credential verification time < 1 second 1 Data rate RS-485 : 9.6 kbps Visual/audible communications Tri-colored LED's and audible indicators (field configurable) System interface Wiegand or Clock & Data via PIB300 or RS-485 directly Power supply 12 VDC or 24 VDC Voltage range 4 VDC to 26 VDC Max current requirement Up to 250 mA Cable specifications for power 18AWG, 2 conductor (Belden 8760 or equivalent) Cable distance for power AD-300 to power supply: up to 1000 (303 m) Cable specifications for data 24AWG, 2 or 4 conductor shielded (Belden 9841, 9842 or equivalent) Cabling distance for data AD-300 to PIB300 or ACP, RS-485: up to 4000 (1219 m) Operating temperature -31° to 151°F (-35° to 66°C) Operating humidity 0 - 100% non-condensing Certifications ANSI/BHMA A156.25, ANSI/BHMA Grade 1, UL 294, UL10 C, FCC Part 15, ADA, RoHS Accessories Panel Interface Board (PIB300), SUS-A Cable used with SUS Android mobile app, Dry Contact Relay Board (RLBD) may be required for supervised inputs (Wiegand systems) PIB300-2D specifications Communication range PIB300 to lock, RS-485: up to 4000 (1219 m) PIB300 to ACP, Wiegand or Clock & Data: up to 500 (152 m) Visual/audible 13 LEDs for status indicators System interface Wiegand or Clock & Data Power supply 12 VDC or 24 VDC Voltage range 9.5 VDC to 26 VDC Max current requirement Up to 250 mA Operating temperature -31° to 151°F (-35° to 66°C) Dimensions (H x W x D) 7.1" x 7.1" x 3.0" (18.0 cm x 18.0 cm x 7.6 cm) Weight 1.25 lb (.57 kg) Cable specifications (PIB300 to ACP) 22AWG, 8 conductor shielded (Alpha 1298C or equivalent) Certifications NEMA 1, 4, 4X, 6; UL 294; FCC Part 15; RoHS Directly communicates via RS-485 RS-485 Wiegand or Clock & Data Panel interface board (PIB300-2D) AD-300 AD-300 Access control panel (ACP) Access Control management system Panel Interface Board (PIB300-2D) If the system requires Wiegand or Clock & Data protocol (rather than a direct RS-485 connection), the AD Series open architecture platform connects up to two AD-300 locks to the Panel Interface Board (PIB300 - sold separately, if required) that seamlessly connects to an access control panel or reader interface board. All monitoring is captured at the remote monitoring station. Functions § Classroom/storeroom 2 § Office 2, 3, 4 § Privacy 3, 4 § Apartment 3, 4 Available status signals § Lock/unlock status 5 § Request-to-exit § Door position § Mechanical key override 3 § Deadbolt position 3 § Interior cover tamper guard 3 § Communication status 3 § Interior push button 3 § Request-to-enter 3 1 Lock requires less than 100 msec, response time does not include latency time of ACP. 2 Classroom/storeroom and office function not available with mortise deadbolt option. 3 Consult your PACS provider for specific scope of support. Interior pushbutton, mechanical key override and deadbolt position are only available when linked via PIM400-485. 4 Not available on exit trim. 5 Soware indicates lock/unlock status based on sequence of events, but cannot validate mechanical clutch position unless monitored on RS-485 connection.

Articles in this issue

view archives of EN-Synergis Locks - Allegion Schlage AD-300 Networked hardwired electronic lock