Vulnerability affecting the Media Gateway role of Security Center
A high-security vulnerability which can lead to the disclosure of video data has been discovered for the Genetec Security Center product line. This vulnerability has been disclosed privately by a third-party organization hired by Genetec to conduct penetration tests on Security Center. There is currently no evidence of this vulnerability being exploited to attack Security Center systems.
Risk assessment
This vulnerability affects the Media Gateway role in its default configuration and can be used to access video data in an unauthorized fashion via the RTSP protocol. An attacker can leverage this vulnerability to retrieve any video data stored in the system or currently being streamed by a camera. The CVSS v3.0 base score for this vulnerability is 7.5 (High).
Details
The Media Gateway role is automatically created when the Web Client Server role is created. Alternatively, the role can also be created manually. Upon creation, a default user is set up without a password. This user has access to all cameras. An attacker can use those credentials to access the video feeds. Systems for which the Media Gateway role is not created or for which the role is deactivated are unaffected by this vulnerability.
This vulnerability affects Security Center 5.6 and some 5.7 versions. Security Center 5.8 and all of the cloud services managed by Genetec are not affected by this vulnerability. See the table below for more details.
Recommendation
Genetec recommends updating to Security Center 5.8 or Security Center 5.7 SR6 to correct the vulnerability.
Alternatively, since the vulnerability is introduced by a configuration issue, it is also possible to set a strong password for this user in the properties page of the Media Gateway role to correct the issue. No changes are required in the Web Client Server role after this configuration change.
See KBA-78996 explaining how to modify the authorized user list of the Media Gateway Role for more details.
Workarounds
If the security patches or the configuration changes can’t be applied in a timely fashion, it is possible to block the Media Gateway listening port at the enterprise perimeter firewall. The default port value is 654.
Affected products
Product |
Affected? |
Details |
Security Center 5.8 |
No |
|
Security Center 5.7 SR6 |
No |
On fresh install: No default user created |
Security Center 5.7 GA to SR5 |
Yes, if Media Gateway Role is enabled with default config |
|
Security Center 5.6 |
Yes, if Media Gateway Role is enabled with default config |
|
Security Center 5.5 |
Yes, if Media Gateway role is created manually and used with default config |
|
Security Center 5.4 |
No |
|
Security Center 5.3 |
No |
|
Security Center 5.2 |
No |
|
Security Center SaaS Edition |
No |
|
To log in to the Genetec Portal, you must be a Security Center user with the appropriate credentials. If you do not have access credentials, please contact channelsales@genetec.com.
For more information or assistance please log in to the Genetec Technical Assistance Portal (GTAP) to open a ticket.